There are 3 main ways to save and recall presets with the Crestron Smart Graphics using the Autonomic MMS device symbol:

  1. Using the MMS control protocol

When sending MMS protocol commands within the Autonomic MMS device symbol in Crestron, all protocol commands will need to be prefixed with MMSProtocol: followed by the protocol command and send via serial string to the *_config signal.

Please see KB article on storing and recalling presets  Programmatically using Presets

Storing and Recalling the same presets to the *_config signal in the Autonomic MMS Device Symbol would look like below:

2. Using the Autonomic device symbol Serial signal  

*_Preset_Select_Text.

To recall a preset using the *_Preset_Select_Text, you must first populate the *_Preset_Select_Text signal with only the preset name (a Serial I/O can be used for this). Once the name is populated, to recall the preset you need to pulse the digital signal *_Recall_Preset.

For example to recall the Party Time preset on Player A you would send "Party Time" to Player_A_Preset_Select_Text, then pulse the digital Player_A_Recall_Preset.

3. Using the Autonomic device symbol Analog signal  

*_Preset_Select.

To recall a preset using the *_Preset_Select, you must first populate the *_Preset_Select signal with a preset number. . Once the number is populated, to recall the preset you need to pulse the digital signal *_Recall_Preset. 