Required Settings for eSeries Mirage Audio System to enable communication between eSeries servers and eSeries amplifiers.
Multicast (UDP) communication is required between servers and amplifiers on 239.195.188.235
The necessary communication port for this UPD traffic is defined as 17089 + MAS System ID. eSeries devices use System ID 1 by default, so Multicast (UDP) communication would occur between servers and amplifiers over port 17090. Changing the System ID to 5, for example, would require communication over port 17094.
Additional TCP Ports used:
23: MMS configuration command line
5004 and 5006: MMS control protocol
80, 5005, and 5050: MMS web interfaces (control and configuration)
17037: amplifier control
17038: amplifier diagnostics
17056: amplifier firmware updates
See /wiki/spaces/ITD/pages/83296338 for additional information on Airplay.