Network and Port Requirements for eSeries MAS

Required Settings for eSeries Mirage Audio System to enable communication between eSeries servers and eSeries amplifiers.

  • Multicast (UDP) communication is required between servers and amplifiers on 239.195.188.235

  • The necessary communication port for this UPD traffic is defined as 17089 + MAS System ID.  eSeries devices use System ID 1 by default, so Multicast (UDP) communication would occur between servers and amplifiers over port 17090. Changing the System ID to 5, for example, would require communication over port 17094.

Additional TCP Ports used:

  • 23: MMS configuration command line

  • 5004 and 5006: MMS control protocol

  • 80, 5005, and 5050: MMS web interfaces (control and configuration)

  • 17037: amplifier control

  • 17038: amplifier diagnostics

  • 17056: amplifier firmware updates

See https://autonomic.atlassian.net/wiki/spaces/ITD/pages/83296338 for additional information on Airplay.