MMS-3e and MMS-5e devices running firmware 6.6.20230705.0/7.2.20230705.0 will, by default, reduce power consumption and hardware strain by powering down non-essential sound hardware after periods of inactivity. This is enabled by default but can be disabled by opening a telnet session to port 23 and sending:

...

Code Block
OverrideAudioHardwarePowersaveMode False

The MMS runtime environment must meet the following conditions for automatic reboots power management to occur:

...

  • There must not have been any activity on the system configuration page within the past 60 seconds

  • There must have been no new control connections within the past 15 minutes

  • There must have been no browse activities from any existing control connection within the past 15 minutes

  • There must not be any pending schedules within the next 10 minutes

  • There must not be any active playback on any output management by the dedicated sound hardware in question.

    • MMS-3e: Player A and Player B

    • MMS-5e: Player A through Player D

...