...
The functionality must be enabled per aforementioned command
Uptime System uptime must exceed 3 days
There must not have been any activity on any configuration page within the past 15 minutes
There must not be an active firmware update in progress
There must have been no new control connections within the past 15 minutes
There must have been no browse activities from any existing control connection within the past 15 minutes
There must not be any pending schedules within the next 10 minutes
There must not be any active playback on any output
AMB Behavior
Once configured as enabled, MMS will additionally instruct any AMB in its System ID or any AMB in Global Mode to reboot, given all other conditions have been met. AMBs will only reboot if they are not actively playing anything.