Applies to: MMS-5e, MMS-3e, MMS-1e

eSeries MMS devices running firmware 6.6.20230705.0/7.2.20230705.0 can be configured to automatically reboot after periods of inactivity. This is currently disabled by default but can be enabled by opening a telnet session to port 23 and sending:

EnableAutomaticReboot True

Subsequently, the functionality can be disabled by sending:

EnableAutomaticReboot False

The MMS runtime environment must meet the following conditions for automatic reboots to occur:

  • The functionality must be enabled per aforementioned command

  • Uptime must exceed 3 days

  • There must not have been any activity on any configuration page within the past 15 minutes

  • There must not be an active firmware update in progress

  • There must have been no new control connections within the past 15 minutes

  • There must have been no browse activities from any existing control connection within the past 15 minutes

  • There must not be any pending schedules within the next 10 minutes

  • There must not be any active playback on any output