Applies to: MMS-5e, MMS-3e, MMS-1e
eSeries MMS devices running firmware 6.6.20230705.0/7.2.20230705.0 can be configured to automatically reboot after periods of inactivity. This is currently disabled by default but can be enabled by opening a telnet session to port 23 and sending:
EnableAutomaticReboot True
Subsequently, the functionality can be disabled by sending:
EnableAutomaticReboot False
The MMS runtime environment must meet the following conditions for automatic reboots to occur:
The functionality must be enabled per aforementioned command
Uptime must exceed 3 days
There must not have been any activity on any configuration page within the past 15 minutes
There must not be an active firmware update in progress
There must have been no new control connections within the past 15 minutes
There must have been no browse activities from any existing control connection within the past 15 minutes
There must not be any pending schedules within the next 10 minutes
There must not be any active playback on any output